Caldwell
Local Reviews
for Caldwell, NJ
Professional mechanic
John - Caldwell, NJ 07006
Knowledgeable professional that did the job correctly and was a pleasure to work with.
Good service
Adam - Caldwell, NJ 07006

Dwayne P.

George W.

Sean W.

Mike P.

Mike P.

George W.
*AUTOMATIC BASED ON JOHN 10/03/19 John 862-596-0059 Annual Extinguisher Inspection (2 extg.) Tech Arrival: MON,TUE,THUR 9AM-8PM(WED 9AM-3PM, FRI 9AM-6PM

George W.
Semi-Annual Inspection See previous report Scheduled with Iris 973-941-0544 Email: information@bluerosevenue.com

George W.
Semiannual Kitchen Inspection Scheduled with Adam #973-226-2122

Mike P.

Kossi A.

Mike P.

George W.
Return to finish job........ Scheduled with Taulant 973-228-1200 Ext. 112 Thank you for the opportunity to review the fire protection needs of your Main kitchen cooking facility and the Amerex 6.14 gal wet chemical system. Based on recent site survey, your appliances and the piping layout of the existing system, we need to modify existing nozzle coverage and move a couple nozzle drops for correct appliance coverage. Replace existing detection tubing. Supply New 1 1/4" Amerex gas valve and hook up to control. (installation of valve by others). Supply and install Baffle filters for all hoods and perform Amerex 6 gallon Hydro test of cylinder. PROJECT SCOPE TO INCLUDE: (1) New Amerex 1 1/4" mechanical gas valve (9) New Amerex rubber nozzle caps (6) New baffle filters (1) New filter spacer System inspection and certification with Report (misc) pipe and fittings

George W.
Scheduled with Taulant 973-228-1200 Ext. 112 Thank you for the opportunity to review the fire protection needs of your Main kitchen cooking facility and the Amerex 6.14 gal wet chemical system. Based on recent site survey, your appliances and the piping layout of the existing system, we need to modify existing nozzle coverage and move a couple nozzle drops for correct appliance coverage. Replace existing detection tubing. Supply New 1 1/4" Amerex gas valve and hook up to control. (installation of valve by others). Supply and install Baffle filters for all hoods and perform Amerex 6 gallon Hydro test of cylinder. PROJECT SCOPE TO INCLUDE: (1) New Amerex 1 1/4" mechanical gas valve (9) New Amerex rubber nozzle caps (6) New baffle filters (1) New filter spacer System inspection and certification with Report (misc) pipe and fittings

Kossi A.

George W.

George W.

Dwayne P.

Tyshon M.

Darren P.

Roland V.
Confires is dedicated to serving our customers throughout New Jersey, Eastern Pennsylvania and Northern Delaware! We take pride in the “customer first” reputation we’ve built the past 40 years. Our customers trust us to guide them through the process of meeting fire protection code requirements and keeping their businesses fire safe.